Select the Installation Location

Click an image to expand

Select the installation location

Location for Installing Indoor Unit

  • Where there is no obstacle near the air outlet and air can be easily blown to every corner.
  • Where piping and wall hole can be easily arranged.
  • Keep the required space from the unit to the ceiling and wall according to the installation diagram on previous page.
  • Where the air filter can be easily removed.
  • Keep the unit and remote controller 1m or more apart from television, radio etc.
  • To prevent the effects of fluorescent lamps, keep as far as possible.
  • Do not put anything near the air inlet to obstruct it from air absorption.
  • Where there is strong enough to bear the weight and is not tend to increase operation noise and vibration.
  • Do not install above the entrance i.e. door or in front of the door. Installation area should have sufficient strength and durability.
  • IDU should not install far away from desired cooling area.
  • Do not place any electronic equipment below the IDU unit.
    Ex: LCD, Computer etc.
Indoor unit installation diagram showing height limits less than 5m and pipe length 15 meters max

Location for Installing Outdoor Unit

  • Where it is convenient to install and well ventilated. Do not install ODU face to face. Avoid the installation in South and West direction.
  • Avoid installing it where flammable gas could leak.
  • Keep the required distance apart from the wall.
  • Installation connecting pipe length provided with this model to be considered as a standard length to connect indoor and outdoor units.
  • Keep the outdoor unit away from a place of greasy dirt, vulcanization gas exit.
  • Avoid installing it at the roadside where there is a risk of muddy water.
  • A fixed base where is not subject to increasing operation noise.
  • Where there is not any blockage for air outlet. Do not install in shaft. Installation area should have sufficient strength and durability. To get optimum efficiency, install under shed.
Outdoor unit installation diagram showing outdoor unit positioned higher than indoor unit with pipe length and height limits
Limit of Tubing
Length (m)
Limit of Elevation
Difference H (m)
*Required amount of additional refrigerant exceeding 3m pipe length (g/m)
15 5 15

*Be sure to add the proper amount of additional refrigerant.
Failure to do so may result in reduced performance.