Select the installation location
Location for Installing Indoor Unit
- ♦Where there is no obstacle near the air outlet and air can be easily blown to every corner.
- ♦Where piping and wall hole can be easily arranged.
- ♦Keep the required space from the unit to the ceiling and wall according to the installation diagram on previous page.
- ♦Where the air filter can be easily removed.
- ♦Keep the unit and remote controller 1m or more apart from television, radio etc.
- ♦To prevent the effects of fluorescent lamps, keep as far as possible.
- ♦Do not put anything near the air inlet to obstruct it from air absorption.
- ♦Where there is strong enough to bear the weight and is not tend to increase operation noise and vibration.
- ♦Do not install above the entrance i.e. door or in front of the door. Installation area should have sufficient strength and durability.
- ♦IDU should not install far away from desired cooling area.
- ♦Do not place any electronic equipment below the IDU unit.
Ex: LCD, Computer etc.
Location for Installing Outdoor Unit
- ♦Where it is convenient to install and well ventilated. Do not install ODU face to face. Avoid the installation in South and West direction.
- ♦Avoid installing it where flammable gas could leak.
- ♦Keep the required distance apart from the wall.
- ♦Installation connecting pipe length provided with this model to be considered as a standard length to connect indoor and outdoor units.
- ♦Keep the outdoor unit away from a place of greasy dirt, vulcanization gas exit.
- ♦Avoid installing it at the roadside where there is a risk of muddy water.
- ♦A fixed base where is not subject to increasing operation noise.
- ♦Where there is not any blockage for air outlet. Do not install in shaft. Installation area should have sufficient strength and durability. To get optimum efficiency, install under shed.
| Limit of Tubing Length (m) |
Limit of Elevation Difference H (m) |
*Required amount of additional refrigerant exceeding 3m pipe length (g/m) |
|---|---|---|
| 15 | 5 | 15 |
*Be sure to add the proper amount of additional refrigerant.
Failure to do so may result in reduced performance.